Engineering Acoustic Instrument - GSY-1 Specificaton & Trade Terms
Model | GSY-1 |
---|
Place Of Origin | Geological instrument |
---|
Price Term | EX-Work |
---|
Payment Term | T/T |
---|
Main Applications and Features
Mainly used for sonic and ultrasonic detection; it can be applied in Nondestructive Testing (NDT) of rock mass and concrete, census (general survey) and follow-up of construction quality, single-hole logging, cross-hole logging. Widely used in testing of strength, internal defects, cracks, joint surface quality and damaged layer thickness, pile foundation quality, sonic logging and parameters of material elasticity, etc.
Technical Parameter
Number of Transmitting Channels: 1
Transmitting Voltage: 100/250/500/750/1000V Optional
1~100μS Adjustable
Pulse Interval: 100ms
Number of Receiving Channels: 2
Adopted Interval: 0.05, 0.1, 0.2, 0.4, 0.8, 1.6, 3.2, 6.4μs
Sampling Length: 512, 1024, 2048, 4096
Triggering Mode: Single, Continuous
Sampling Mode: Single, Continuous, Superposition
Pass Band: 10~250 KHz
Pre-amplification: -20dB (1/10), -14 dB (1/5), -6 dB (1/2), 0dB (1), 6dB (2), 14dB (5), 20dB (10), 26dB (20), 34dB (50), 40dB (100), 46dB (200), 54dB (500), 60dB (1000), 66dB (2000), 74dB (5000), 80dB (10000), Program-Controlled Adjustment
Probe Specifications
Parameter\Model
ST-1A
(Single-Transmit and Double-Receive Type)
ST-2
(Cross-Hole Type)
ST-3
(Wall-Adherent Type)
Maximum Outside Diameter (mm)
32, 45
34 (can be made as per customer requirement)
44, 56
Dominant Frequency (Hz)
35K, 25K
35K
61K/52K
Spacing for 2-channel receiver tube (mm)
200
Spacing for transmitting and 1-channel receiver tube (mm)
300
Cable Length (mm)
30, 50, 60, 100,
30, 50, 60, 100
Lithology recognition
Application
Detect the rock mass surface layer, water layer, levee surface faultage and rock mass crack developmental conditions.
Detection of concrete for pile driver, etc.
Used for quality inspection of core and various materials