stator testing panel - ND-ST023 Specificaton & Trade Terms
Model | ND-ST023 |
---|
Place Of Origin | China |
---|
Packaging | wooden case which is suitable for sea transport |
---|
Brand | Nide |
---|
Certifications | ISO9001 |
---|
Price Term | FOB or CIF |
---|
Payment Term | T/T or L/C |
---|
Minimum Order | 1 set |
---|
Loading Ports | Ningbo or Shanghai |
---|
Delivery Time | 60 days |
---|
Basic configuration
1. Tester Max dimension: 850(width)*950(depth)*1870(height), surface plastic blast, white color computer. Electric cabinet in good ventilation condition and mouse proof.
2. Two working position could rotary test. The height of working position is 790mm,working station dimension is 460(depth)*800(width)
3. Computer system with CPU1.3G,internal save capacity 128M,harddisk 80G,15"colorful display screen
4. Connector and sampling circuit from Japan and U.S.A
5. Windows 2000 operation system
Test item and Techenical Specification
1. Cooling state resistance test
Test method Four points,with auto correctting ambient temperature function, the standard temperature can be set, wire connection according to buyer's requirement.
Test range 1Ω--200Ω
Test tolerance ±1%
2. Dielectric strength
Pass high voltage between core and winding
Test condition AC 0-3000V adjustable.
Voltage tolerance ±3%
current leakage range 0.1-10mA
Current tolerance ±1%
Time 1s~60s(software setting)
3. Insulation Resistance
Test condition DC 500V
Range 10MΩ~2000MΩ
Tolerance 10MΩ~200MΩ ±3%
Above 200 MΩ, the tolerance is negligible
4. Turn to Turn Insulation
Test condition Taking a qualified stator as the standard sample, and save its test curve and data in computer. Then comparing the values of standard one and the to-be-tested stator, calculating the area and the relative error value of frequency , and then figure out the upper limit value of relative error value.
Pulse voltage peak value 500V-3000V
Pulse peak value tolerance ±5%
Criterion value setting conclude as per the percentage of
S and f, setting range is 1%-99%
5. Polarity test
Test condition Electrify the motor stator DC current, judge the polarity direction of the stator by Hall element.
Criterion value setting Alert when the direction of polarity is different from the setting.